• DIGITAL VIBRATION CONTROL SYSTEM Model:DCS-98000MJ

The DCS-98000MJ series vibration control system is the most suitable digital vibration control system used for an electrodynamic vibration testing system to perform vibration evaluation test for highly advanced industrial products.
[Control Package Specifications]
Software Random vibration control package
Model ESP-101ME
Frequency range 100,200,500,1000,2000,5000Hz
Reference profile Breakpoint (Hz), Power Spectrum Density (PSD) and slope
 
Software Sine vibration control package
Model ESP-201ME
Frequency range 0.1 to 10000Hz
Reference profile Breakpoint (Hz), Acceleration, Velocity, Displacement
Other feature Resonant dwell control
 
Software Shock control package
Model ESP-301ME
Shock pulse Half-sine, Sawtooth, Haversine, Trapezoidal, Any user synthesized waveform
Pulse duration 10.0 to 100 ms for default pulse
 
Software Transfer function equalization control package for any waveform
Model ESP-401ME
Frequency range 100,200,500,1000Hz
Control strategy Output level control, PSD control, transfer function equalization
• DIGITAL SINE CONTROLLER Model: 208-A

The 208-A digital sine controller is designed to perform sine vibration tests. Its control technology uses an analog-to-digital conversion method of changing resolution and synchronous integration, therefore, it permits to finish a measurement in only one cycle (@1/50 resolution) to accomplish the required vibration control. The display part is simplified to realize the low cost controller.
[Control Package Specifications]
Programming mode Sweep, point, batch process
Frequency range 1.00 to 10000.00Hz
Input range 0.05 to 100000pC or 0.005 to 10000mV
Output voltage 0.1 to 5000mV
Dimensions 440W X 63H X 380Dmm
Mass 5.3 kg or app.
 
• DIGITAL SHOCK CONTROL SYSTEM Model: 271-B

The control system is specifically designed for FS Series Shock Test System. All the features needed for reproducing the popular haversine shock pulse and any time trace (actual field waveform) and for creating a user’s own custom pulse, not to speak of classical shock pulse most commonly used until now are implemented. The 271-C allows to easily perform acquisition and reproduction of user’s data and trimming and equalizing unnecessary data. All the test conditions and operations can be extremely readily defined on a keyboard in an interactive manner.
[Hardware Specifications]
Input channel 4CH
Analog input voltage 5VP-P( ± 2.5V)max
Resolution 16bit
Input impedance 1MΩ
Analog output voltage 20V( ± 10V)max
Output impedance 100Ω
Display monitor 15inch Color CRT
Input power AC100V 50/60Hz
Coated color EMIC’s standard color (Code:EC30) for panels of our own products, but manufacturer’s standard color for computer, etc.

[Software Specifications]

· Shock Waveform Editor
Available waveform Half sine, trapezoidal, sawtooth, triangular, haversine, any custom waveform (available up to two waveforms), random
Analyzing time 102.4ms to 2.048s
Sampling point Fixed at 2048 points
Sampling speed 50,60,100,120,200,300,400,500,600µs,1ms (Automatically defined depending on a waveform)
Pulse width 1 to 100 ms for classical shock pulse about 5 to 200 ms for random

· Shock Control
Reference waveform Classical shock(half sine, trapezoidal, sawtooth, triangular, haversine), any custom waveform (available up to two waveforms), time historical random and time trace created by shock waveform editor
Control channel 1CH
Control parameter Acceleration(Unit : m/s2,G)
Analyzing time 102.4 ms to 2.048s same as waveform creation using shock waveform editor
Repetition 1 to 99000
Sampling point Fixed at 2048 points
External input 4 CH, but CH1 is for control only
Input channel Any channel selectable from CH2 to CH4