| |
|
|||||||||
| |
|
|
|
|
|
|
|
|
||
| |
||||||||||
![]() |
| Please contact us |
![]() |
Exciting Force | Sine : 176kN PK(18,000kg f)0-p Randam : 151kN PK(15,400kg f)rms |
|
| Frequency Range | (DC) to 2000Hz | ||
| Attached Equipment |
SLIP TABLE SYSTEM | ||
| Max.Velocity | 177cm/s | ||
| Max.Displacement | 51mmP-P | ||
| Maximum Payload | Vertical : 1000kg Horizontal : 5000kg |
||
| Effective Slip Table Saize |
1200 X 1200mm | ||
| |
|||
![]() |
[Test Category] | ||
| HALT | Highly Accelerated Life Test | ||
| HASS | Highly Accelerated Stress Screening | ||
| COMBINED AGREE CERT TEST |
(Vibration/Rapid Thermal transitions/Thermal Shock) Chamber | ||
[Chambe] |
|||
| Interior size | 1370W X 1370H X 1010Dmm | ||
| Temperature Range | -70 °C to +175 °C | ||
| Temperature change rate | 25 °C/min (With mechanical refrigerator) 60 °C/min (Combination with LN2) | ||
[Six DOF Pneumatic vibration system] |
|||
| Table size | 900mm X 900mm | ||
| Generated vibration | Six degrees of freedom, pseudo-random | ||
| Frequency range | 2 to 10000Hz | ||
| Maximum acceleration | 588m/sec2rms | ||
[Electro-Dynamic vibration system] |
|||
| Maximum force power | 35kN PK in sine | ||
| Frequency range | 1 to 2200Hz | ||
| Maximum acceleration | 1000m/s2 | ||
| Maximum velocity | 125cm/s | ||
| Maximum displacement | 60mmP-P | ||
![]() |
CONTRACTED TEST CENTER has become increasingly complete facilities for servicing customers testing work (open to customers)!! |
|
| Our engineer, who is familiar with testing technology, can assist you on request. The specimen-mounting fixture may decide whether or not you can successfully perform a test. We can also accept for designing and manufacturing of such an important fixture suited for your application. We will also do everything to protect the confidentiality of the information. | ||
| * | In addition to the above mentioned equipment, our test facility is completely consisted of various test equipment such as a temperature/humidity combined environmental reliability test system with a slip table system for horizontal vibration tests. We can meet all the need from customers. Please contact us. (Location: Mishima-city in Shizuoka, 15 minutes by a car from Mishima station in Tokaido Shinkansen) |
| We are pleased to help you |
|||||
![]() |
Kazuhiro Haraguchi Test Engineer : 25years experience Test Consultant : 14years experience |
![]() |
Oki Toshikatsu System Engineer : 12years experience Test Consultant : 7years experience |
||
![]() |
Yasushi Tanzawa Products Engineer : 16years experience Test Consultant : 7years experience |
![]() |
Kouichi Goto Field Service Engineer : 11years experience Test Consultant : 5years experience |
||
![]() |
Makoto Kamio System Engineer : 8years experience Test Consultant : 6years experience |
||||
| copyright(c)2002EMIC CORP.All right reserved. | ||||